Choose your country or region
AsiaPacific
Australia
English
Philippines
English
North America
United States
English
Europe
United Kingdom
English
France
Français
Deutschland
Deutsch
Europe
English
España
Español
Italia
Italian
Poland
Polski
Sweden
Swedish
Netherlands
Dutch
Georgia
Грузия
Africa
South Africa
English
EcoFlow OCEAN Meter Backup Switch
  • Product
  • Specs

EcoFlow OCEAN Meter Backup Switch (Dual Units) with IslandDER Meter Socket Adapter by ConnectDER

Faster Setup, Lower Costs

System Overview

The equipment connects to the EcoFlow OCEAN Pro Hybrid Inverter and IslandDER Meter Socket Adapter (MSA) to enable communication between the devices,thereby achieving power detection, anti-backflow protection, and grid-tied/off-grid switching.

Major Functions

  • Streamlined Installation: Plugs into the meter socket with a simple interface box—no main panel upgrades needed, reducing cost and complexity.
  • Real-Time Monitoring: Built-in metering tracks whole-home energy use and grid flow with precise, up-to-the-minute data.
  • Seamless Backup Activation: Automatically disconnects from the grid and switches to EcoFlow OCEAN Pro battery backup in less than 15ms[1] during an outage.

All specifications and descriptions shown may differ from the actual product. EcoFlow reserves the right to make changes and amendments to the product shown or described here at any time without prior notice. All functionality, features, specifications, design, and other product information displayed on this webpage—including, but not limited to, components, performance, availability, and capabilities—are subject to change without notice. The contents and simulated images on the screen are for demonstration purposes only.

*Performance data is based on tests conducted in controlled environments using pre-configured settings. Actual results may vary depending on the environment, system updates, and individual usage patterns.

*This product is currently available only in the state of California. For eligibility and installation details, please consult your installer.

[1] Performance data is based on testing conducted by EcoFlow Labs. Actual results may vary.

Performance Specifications

Grid Type

Split Phase

Nominal Grid Voltage (Input & Output)

120/240 VAC

Voltage Detection (L1-L2)

+/-1% accuracy

Rated Current

200A

Frequency

60Hz

Current Detection

+/-0.5% accuracy

Relay Switch Time

<=15ms

Operating Noise @ 1 m

<=10dB

Warranty

15 years

Maximum Power Consumption

<=5w

Environmental Specifications

Operating Temperature

-22°F to 149°F (-30°C to 65°C)

Storage Temperature

-40°F to 176°F (-40°C to 80°C)

Relative Humidity

0% to 100%, condensing

Environment

Outdoor rated

Enclosure Rating

NEMA 3R

Pollution Rating

PD3

Maximum Elevation

9842 ft (3000 m)

Compliance Information

Safety

System UL1741, UL3141

Structural

Dimensions (L x W x H)

5 x 7.9 x 3 inches (127 x 200.6 x 76.2 mm)

Weight

5.55 lbs (2.52 kg), with Connection Module and 6 ft analog cable

Performance Specifications

Grid Type

Split Phase

Nominal Grid Voltage (Input & Output)

120/240 VAC

Voltage Detection (L1-L2)

+/-1% accuracy

Rated Current

200A

Frequency

60Hz

Current Detection

+/-0.5% accuracy

Relay Switch Time

<=15ms

Operating Noise @ 1 m

<=10dB

Warranty

15 years

Maximum Power Consumption

<=5w

Environmental Specifications

Operating Temperature

-22°F to 149°F (-30°C to 65°C)

Storage Temperature

-40°F to 176°F (-40°C to 80°C)

Relative Humidity

0% to 100%, condensing

Environment

Outdoor rated

Enclosure Rating

NEMA 3R

Pollution Rating

PD3

Maximum Elevation

9842 ft (3000 m)

Compliance Information

Safety

System UL1741, UL3141

Structural

Dimensions (L x W x H)

5 x 7.9 x 3 inches (127 x 200.6 x 76.2 mm)

Weight

5.55 lbs (2.52 kg), with Connection Module and 6 ft analog cable